Product Name. Nominal Length. Tubing I.D. Drop Size. Y Site Type. Number of Y Sites. Product Image. . 5 mL Vial Adapter with Clave Connector.
Use of the Vial Adapter gave better consistency. The standard deviation for a 2 mL withdrawal was substantially lower with the Vial Adapter for all groups see the table . From this it can be judged that delivery volume to the patient will likewise be more consistentand with better volume of delivery it follows that the amount of overfill
Superior Safety and Ease of Use Introducing the 2nd generation of EQUASHIELD Closed System Drug Transfer Device Covers more routes of exposure than alternative systems The only system that prevents syringe plunger contamination repeatedly identified as a major route of exposure to hazardous drugs .
Vacuum Adapter has a ground glass standard taper outer joint on top that provides a convenient leak free way to connect to the OP 6602 OP 6603 and OP 6604 disposable long stem filter funnels and a taper inner joint or a vial.
Call Us. Medical professionals medical facility employees 855.571.2100. Need help with SupplyManager 800.422.0280. Accounts Receivable 800.453.5180
Remove the lid film of the vial adapter packaging but do NOT remove the vial adapter from its packaging. Holding the vial adapter packaging position the vial adapter on top of the vial and push it fully down so that it snaps in place confirmed by an audible click. Lift the packaging off the vial adapter
The vial adapter 32 includes a filter cover 49 for deployment between the top cover 43 and the top skirt wall 36. The filter cover 49 encloses an air filter 51 placed on the radial ribs 39. The air filter 51 has a central air filter aperture 52 co axial with the longitudinal device axis 31.
OnGuard Vial Adaptor. Benefits of OnGuard CSTD Majority of hazardous drug compounding can be done with just 3 SKU. Designed to reduce waste help make implementations easier and reduce confusion. Just compound and go. No need to pre prime or pre activate the vial adaptor. Click to lock. No push and twist. Linear connection designed to
SMARTSITE VIAL ADAPTER 20MM100/CS. With the universal vial adapter hospital personnel do not need to sacrifice safety for simplicity. Unlike other vial adapters this universal vial adapter provides closed needle free access to multiple use drug vials to help reduce the risk of surface contamination during the drug reconstitution process.
The first successful CSTD was Phaseal currently made by BD. When introduced in 1999 it was a revolutionary concept components added to the traditional vial and syringe successfully prevented the escape of droplets vapors and aerosols. During compounding the vial adapter forced vapors and aerosols into an external balloon. Transfer of the
4 Open the Mix2Vial filter transfer set by peeling off the lid. Do not remove the transfer set from the blister package. 5 Place the Sterile Water for Injection vial on an even clean surface and hold the vial tight. Take the transfer set together with the blister package and push the spike of the blue adapter end straight down through
syringe and vial adapter. With the other hand hold the IXINITY vial tightly on a clean flat surface. In a continuous motion place the vial adapter over the IXINITY vial firmly push the filter spike of the vial adapter through the center of IXINITY vial’s rubber circle until the clear plastic cap snaps onto the IXINITY vial See Figure E .
The filter media allows the passage of air to the atmosphere outside the vial for pressure equalization. In another aspect a third filter medium is used in the vent of the adapter to allow gas to pass in either direction through it but prevents bacteria and particulate matter in the atmosphere from reaching the second filter device.
Disposable filter funnel for solid liquid separation can be used in chemistry and biological laboratories. The molded funnel has a 10 micron polyethylene fritted disc. Polypropylene filter funnel is designed for use with the CG 1049 J style glass vacuum adapter and a flask or vial. The CG 1049 J
Syringe will not operate if vial adapter and syringe connector are not properly connected. Forcing plunger may result in syringe leakage and Mitosol exposure. d. Stand vial upright on a sturdy flat surface and push on the vial lid until seated and secure. Fig. 3 e. Inject entire contents of sterile water 1 ml into vial. Fig.
11. Withdraw solution into the syringe by holding the vial on end above the vial adapter and syringe I then draw the plunger rod out slowly and smoothly. Ensure that the entire content of the vial is drawn into the syringe. 12. With the plunger rod in place remove the syringe from the vial adapter the latter should remain attached to the vial .
Universal Vial Adapter 1 Vacuum Bottle 1 Vial Access Adapter 1 Vial Access Cap Spike 1 Y Site Connector 1 Zero Reflux IV Connector 1 Embolization Coil 9 Luer Lock Cap 7 Pressure Monitoring Line 7 Tamper Evident Luer Lock Cap 7 Channel Two Diluent Set 6 Sealed Lead Acid Battery Pack 6 Catheter Repair Kit 5 Inflation
Helapet Vented Vial Adapters are a safe and easy to use solution for reconstitution of cytotoxics antibiotics and other hazardous chemicals. A single use needle free device Helapet Vented Vial Adapters can be securely fastened to any standard 13mm or 20mm diameter vial. The novel skirt design prevents the adapter from being detached once
Company News Filtertek Brings New Vial Adapter to Market. New product designed for various vent and liquid filter options. HEBRON IL January 2006 Filtertek a leading developer of new medical products for healthcare OEM s now offers a new vial adapter and filtration component system to facilitate medication access reconstitution and transfer.
Universal Vial Adapter 1 Vacuum Bottle 1 Vial Access Adapter 1 Vial Access Cap Spike 1 Y Site Connector 1 Zero Reflux IV Connector 1 Embolization Coil 9 Luer Lock Cap 7 Pressure Monitoring Line 7 Tamper Evident Luer Lock Cap 7 Channel Two Diluent Set 6 Sealed Lead Acid Battery Pack 6 Catheter Repair Kit 5 Inflation
For closed reconstitution and withdrawal of medications with most 20 mm and 13 mm vials with vial converter ring provided Majority of hazardous drug compounding can be done with just 3 SKU. Designed to reduce waste help make implementations easier and reduce confusion. Just compound and go. No need to pre prime or pre activate the vial adaptor.
Vial Adapter with 0.22 micron vent and Clave connector. Product Numbers List Number shop.icumed Number EDI Number Filtered No Sterile Pack No Hand Pump No Backcheck Valve No Latex Information Natural rubber latex has not been used in the manufacture of this product Case Information Order Quantity 1 Case 50 Case Size 1 x 50 Cases per Tier 36 Cases per
Vented safe handling vial adapter June 2010 Mosler et al. Syringe devices and methods for mixing and administering medication June 2010 Tennican et al. D616984 Vial adapter having side windows June 2010 Gilboa Method and apparatus for an improved luer fitting connection May 2010 Burton et al. D616090
A vented vial adapter has a filter attached to a vent arm that includes at least two filter media for suppressing aerosolized medicaments from leaving the vial and suppressing bacteria and other contaminants from entering the vial during reconstitution activities of the medication in the vial. The filter media allows the passage of air to the atmosphere outside the vial for pressure equalization.
1. 2. 3. This device partners with the Texium closed male Luer to provide closed system access to drug vials. SmartSite needle free valve includes Needle free access to multiple use vials. 0.2 micron hydrophobic air venting filter provides Neutralization of vial pressure minimizing aerosols and surface contamination. Eases drug extraction.
Methods of venting a vial adapter with aerosol retention . United States Patent . Abstract A method for retaining aerosols when accessing a sealed vial is disclosed. The method includes the steps of piercing the vial seal with a sharp cannula having a medicament lumen and a vent lumen introducing a liquid through the medicament lumen
enters the vial. To fully seat the adapter to the top of the vial push downward while rotating adapter a full 720 degrees Prepare vial 1 6. Swab the top of the needle free valve with 70 IPA and allow it to dry 7. Connect the syringe to the needle free valve on a hard and flat surface 8. Inject the desired amount of diluents into the vial
Single Vial Adapter for attaching one 10R reagent vial to a CliniMACS Prodigy Tubing Set.Sterile and non pyrogenic fluid path.One package unit contains five pieces of sealed Single Vial Adapters for single use. Great Britain
Vial adapters are a cost effective solution for the safe and rapid transfer and reconstitution of drugs between vials and syringes. Vial adapter spike technology provides a reproducible engineered depth. for drug and diluent aspiration which greatly reduces the end user variability associated with traditional needle aspirations and helps
A vented vial adapter has a filter attached to a vent arm that includes a t least two filter media for suppressing aerosolized medicaments from leavin g the vial and suppressing bacteria and other contaminants from entering the vial during reconstitution activities of the medication in the vial.
ViaLok Vented Vial Access Device The ViaLok Vented Vial Access Device is designed with a 0.2 micron filter to allow for venting during fluid withdrawal. 20 mm standard closure Universal Easy attachment and superior vial security Integrated grip reduces user
Closed Vial Adaptor. Halo’s Closed Vial Adaptors are intended for closed preparation of drugs. The system is compatible with standard vials with 13mm 20mm and 28mm OD necks which correspond to CVA130 CVA200 and CVA280 respectively.
4. Insert the vial in counting adapter the disc facing the detection opening and count WM 10 15 Fig. 1. A glass fiber filter disc adhered to the inner wall of a 20 ml vial. Wet method WM 1. According to your preference wipe with a dry or moistened disc. 2. Insert the disc in the vial. Minivial is recommended. 3.
5 Building a vial assembly using an assembly fixture M12 O Equipment necessary 1. BD PhaSeal Optima Protector according to neck size of the vial 2. BD PhaSeal Optima assembly fixture M12 O 3. Drug vial s 1 Place the assembly fixture on the work surface. 2 Remove the vial cap and disinfect per facility protocol. Place the vial on the assembly fixture
The enhanced inline vent filter allows quick and efficient equalisation of sterile air in the vial for improved flow rates and effortless withdrawal. Providing stable needle free access to standard 13mm and 20mm drug vials the Helapet Vented Vial Adapter range supports safe and precise drug reconstitution whilst preventing exposure to
5 Building a vial assembly using an assembly fixture M12 O Equipment necessary 1. BD PhaSeal Optima Protector according to neck size of the vial 2. BD PhaSeal Optima assembly fixture M12 O 3. Drug vial s 1 Place the assembly fixture on the work surface. 2 Remove the vial cap and disinfect per facility protocol. Place the vial on the assembly fixture